Description:
Trajan SGE OptChem™ 09262111 Taper FocusLiners with Pre-Fitted CRS ONE o-Ring, 2.3 mm ID, length 78.5 mm. This Trajan SGE Tapered FocusLiner® GC inlet liner is designed for split/splitless injections, uses a unique design to hold the quartz wool in the correct position, offering robust and durable for longer life, less maintenance downtime and reduced maintenance costs. Trajan SGE OptChem™ GC inlet liners provide optimal performance with advanced coating technologies in an easy-to-use format for GC and GCMS. These liners are fitted with CRS ONE O-rings. Suitable for trace level analysis, volatile and organochlorine pesticides (OCPs), pesticides, persistent organic pollutants (POPs), brominated flame retardants (BFRs), dirty samples, and general-purpose GC and GCMS. (5/pack).
MODEL COMPATIBILITY:
Agilent Intuvo 9000, Agilent 8890, Agilent 8860, Agilent 7890, Agilent 6890, Agilent 6850, Agilent 5890, Agilent 4890, Bruker/Varian 1177, Lucidity GC-FID, PerkinElmer GC 2400, Clarus 690, Clarus 590, Scion 8500, Scion 8300; Thermo Scientific, Thermo Trace 1600, Thermo 1610, Thermo 1300 & Thermo GC Ultra gas chromatographs.
FEATURES AND BENEFITS:
MODEL COMPATIBILITY:
Agilent Intuvo 9000, Agilent 8890, Agilent 8860, Agilent 7890, Agilent 6890, Agilent 6850, Agilent 5890, Agilent 4890, Bruker/Varian 1177, Lucidity GC-FID, PerkinElmer GC 2400, Clarus 690, Clarus 590, Scion 8500, Scion 8300; Thermo Scientific, Thermo Trace 1600, Thermo 1610, Thermo 1300 & Thermo GC Ultra gas chromatographs.
FEATURES AND BENEFITS:
- OptChem™ deactivation is a unique thick film which limits breakdown, ensuring minimal loss of sample and increased system sensitivity
- Quality tested to USEPA 8081: organochlorine pesticides, and USEPA 8270: semivolatile organic compounds to ensure a high level of inertness
- Pre-fitted with CRS ONE o-rings to reduce contamination from handling
- Touchless packaging format reduces the risk of contamination during installation
- Bottom taper focuses sample onto the head of the column and minimises contact with metal parts of the inlet
- A taper at the top aids in minimising sample flashback
- Ensures quartz wool remains in the correct position within the liner
- Excellent reproducibility results from the wiping of the sample from the syringe needle and the prevention of droplet formation.
Specifications:
Injection Technique | Split / splitless |
Geometry | OptChem™ Tapered FAST FocusLiner |
OD (mm) | 6.3 |
ID (mm) | 2.3 |
Length (mm) | 78.5 |
Qty./Pk | 5 |