Photo of TCS PTFE/Silicone Septa. SGE
TCS septa are designed for medium to high temperature applications. This septa is a PTFE-faced with a triple layer of silicone underneath. Maximum temperature is 280° C. All septa are pre-conditioned, bleed checked and packaged ready for immediate use.
Photo of SGE Signet GP Grade Low Temperature Injection Port Septa

SGE Signet GP Low Temperature Silicone Septa combine significantly longer injection life, low bleed and low injection port adhesion. GP Septa offer good durability, resealing and tear resistance properties, along with excellent solvent resistance. Intended for low temperature applications, they are blister packed to prevent absorption from the environment. These septa are suitable for a maximum injector temperature of 200°C.

(Sample Photo Displayed. Individual items may differ from the image shown.)

 

Photo of Auto-Sep™ Silicone Septa. SGE
Auto-Sep™ is a higher temperature (320° C) silicone septa developed specifically for high volume autosampler and manual injection use. Made from soft silicone compound, Auto-Sep™ is designed to facilitate easy needle penetration, eliminating the need for pre-drilled septa, and maximum tear resistance to ensure a long operating lifetime. Suitable to use with all detector systems (FID, ECD, MSD's), Auto-Sep™ is pre-conditioned, bleed checked (batch) and packed in non-contaminating glass containers ready for immediate use. Ideal for use with High/Low speed autosamplers.
Photo of Ferrules for Varian Instruments. SGE
SilTite™ metal ferrules have been developed specifically for use with GC/MS systems and have distinct advantages over graphite and composite ferrules for use with GC/MS interfaces. The metal SilTite™ ferrule and nut are made from the same material and therefore have the same thermal expansion coefficient. As the oven heats up and cools down, the nuts and ferrules expand and contract at the same rate, eliminating annoying leaks and the need to retighten the ferrule after installation. SilTite™ nuts are reusable.
Photo of Ferrules for Shimadzu Instruments. SGE
SilTite™ metal ferrules have been developed specifically for use with GC/MS systems and have distinct advantages over graphite and composite ferrules for use with GC/MS interfaces. The metal SilTite™ ferrule and nut are made from the same material and therefore have the same thermal expansion coefficient. As the oven heats up and cools down, the nuts and ferrules expand and contract at the same rate, eliminating annoying leaks and the need to retighten the ferrule after installation. SilTite™ nuts are reusable.
Photo of SGE Trajan Ferrules for Agilent Technologies Instruments

SilTite™ metal ferrules have been developed specifically for use with GC/MS systems and have distinct advantages over graphite and composite ferrules for use with GC/MS interfaces. The metal SilTite™ ferrule and nut are made from the same material and therefore have the same thermal expansion coefficient. As the oven heats up and cools down, the nuts and ferrules expand and contract at the same rate, eliminating annoying leaks and the need to retighten the ferrule after installation. SilTite™ nuts are reusable.

Photo of BP20 (Wax) Polyethylene Glycol GC Column. SGE
The BP20 (Wax) capillary column has a very polar phase suited to the analysis of alcohols, ketones and aldehydes. Also offers excellent separation of aromatic isomers such as the xylene isomers. Operating temperature range is 20 to 260/280° C. Suitable replacement for: AT-Wax, CP Wax 52CB, DB-Wax, HP20M, HP-INNOWax, HP-Wax, Nukol, Rtx-Wax, Stabilwax, Supelcowax-10.
Photo of BPX1 100% Dimethyl Polysiloxane GC Columns. SGE
A 100% polydimethylsiloxane non-polar column for Simulated Distillation in the petroleum industry. This column is coated with a custom-designed phase which gives low, consistent bleed and is ideal for background subtraction. The column is used for ASTM methods D2887 and D6352 and has a maximum temperature up to 430°C for the aluminum clad column. Suitable replacement for: DB-2887, DB-HT Sims Dis, HP-1, Petrocol 2887, Petrocol EX2887, Rtx-2887.
Photo of BP1 100% Dimethyl Polysiloxane GC Columns. SGE
Manufactured of the highest quality materials. 100% Dimethyl polysiloxane. Phase attributes include a compatibility with all modern detectors. An excellent general purpose column. Separates components predominantly by boiling point. Low bleed. Non-polar. Suitable replacement for: CP-Sil 5CB, DB- Petro, DB-1, HP-1, HP-1MS, Petrocol DH, Rtx-1, SPB-1, SPB-1Sulfur, Ultra-1.
Photo of BP10 14% Cyanopropylphenyl Polysiloxane GC Column. SGE
This phase (14% Cyanopropylphenyl Polysiloxane) has been selected with a polarity suited for the separation of organochlorine pesticides listed in the EPA 608 and 8081 methods. Operating temperature range is -20 to 280/300° C. Suitable replacement for: CP-Sil 19CB, DB-1701, Rtx-1701, SPB-7.
Photo of BP5 5% Phenyl / 95% Dimethyl Polysiloxane GC Column. SGE
The BP5 is a general purpose phase capillary column with excellent high temperature characteristics. Popular column used for a wide variety of applications. Operating temperature range is -60 to 340/350° C. Suitable replacement for: CP-Sil 8CB, DB-5, HP-5, MDN-5, PTE-5, Rtx-5, SPB-5, Ultra-2.
Photo of SGE Gas Tight Milliliter Syringes

These SGE Gas Tight Syringes are constructed from borosilicate glass, PTFE plunger tips and Kel-F luer cones where applicable. Gas Tight syringes are assembled with an interference fit between plunger tip and barrel to effect the gas sealing properties of the syringe. Plungers for these syringes are interchangeable. Gas Tight syringes can be autoclaved but the plunger should be removed. These syringes are suitable for both liquid and gas samples for maximum inertness. Also suitable for manual and dispenser/diluter applications.

Photo of SGE Gas Tight 10µL to 500µL MicroVolume Syringes

SGE Gas Tight 10µL to 500µL MicroVolume Syringes are constructed from borosilicate glass, PTFE plunger tips and Kel-F luer cones where applicable. Gas Tight Syringes are assembled with an interference fit between plunger tip and barrel to effect the gas sealing properties of the syringe. Plungers for these syringes are interchangeable. Gas Tight Syringes can be autoclaved but the plunger should be removed. These syringes are suitable for both liquid and gas samples for maximum inertness. Also suitable for manual and dispenser/diluter applications.

Photo of LC Manual Valve Syringes. SGE
SGE offers an extensive selection of Liquid Chromatography syringes for Beckman/Altex, Rheodyne, SSI and Valco valves. All syringe needles are 2" in length x 22 gauge.
Photo of SGE Trajan Headspace Soil Gas Syringes

These syringes are available in 5 and 10mL capacities. They are fitted with a valve (SVLL) and a special Luer Probe with a side hole for efficient sample intake. The probe is placed in position and the Head-space sample is taken and locked into the syringe using the valve. The probe is then removed from the syringe, and a Luer needle fitted (supplied) and injection made.

(Sample Photo Displayed. Individual items may differ from the image shown.)

 

 

Photo of SGE Trajan Jumbo Gas Sampling Syringes

Jumbo syringes are ideal for calibration of medical equipment such as respirators, spirometers and also for stack and air sampling.

  • Designed for holding and dispensing large volumes of gas

  • Heavy duty acrylic barrels

  • Easy access to sample for the addition of standards or removal of subsample via secondary port

  • Plunger stem can be unscrewed for ease of transportation and storage

(Sample Photo Displayed. Individual items may differ from the image shown.)

 

Photo of SGE Plunger-in-Needle 0.5µL to 5µL NanoVolume Syringes

SGE Plunger-in-Needle NanoVolume Syringes have the ability to inject down to 50nL with high precision and accuracy. They are perfect for nanovolume capillary chromatography injection. The sample is only drawn up into the needle, not the syringe barrel.  When the plunger is depressed, the sample is completely dispensed by the NanoVolume plunger that extends right to the tip of the needle. Note: The plungers and needles are matched sets and must be replaced as a set.

Photo of SGE Trajan GC Autosampler Syringes for Varian Bruker Instruments

These GC autosampler syringes are designed and tested to meet critical autosampler specifications. Unique plunger design minimizes bending and seizing, and the cone tip needle point style has been developed specifically to withstand multiple fast septum injections.

(Sample Photo Displayed. Individual items may differ from the image shown.)

 

Photo of GC Autosampler Syringes for Thermo Finnigan Instruments. SGE
GC Autosampler Syringes designed to fit Thermo Finnigan Instruments; AS200, AS800 and AS2000. All syringes have cone style tips.
Photo of 5 to 10µL Guided Plunger Microliter Syringes. SGE
SGE's guided plunger microliter syringes are manufactured with an extended barrel and a guided plunger to virtually eliminate plunger bending. This allows the user to concentrate on sample delivery rather than the syringe's performance. Barrel of syringe is marked with sharp and clear fused graduations. Recommended for rugged applications where extended syringe life is important.