Nalgene (Thermo Scientific Inc.)

Photo of 25mm Glass-Fiber Syringe Prefilter. Nalge
This glass-fiber prefilter syringe filter is for prefiltration and clarification of highly viscous solutions and removal of large particulates from suspensions. Contains no adhesives or binders that can affect results. Modified acrylic housing. Inlet: Female Luer-Lok*; Outlet: Male Luer-Lok. Pore size and membrane type printed on unit. Do not autoclave. Non-sterile. *Registered trademark of Becton Dickinson. WARNING! All NALGENE Filterware is for research use only, not for in vitro diagnosis or parenterals.
Photo of 25mm CA/Glass Syringe Prefilter Plus
Contains 0.2-µm cellulose acetate (CA) membrane with built-in glass-fiber prefilter for sterilization of highly viscous solutions and/or solutions with high particle loads. Modified acrylic housing. Pore size and membrane type printed on unit. Certified sterile, non-cytotoxic and non-pyrogenic. Do not autoclave. Sample volume size: 10-200 mL. Inlet: Female Luer-Lok*; Outlet: Male Luer-Lok. *Registered trademark of Becton Dickinson. WARNING! All NALGENE Filterware is for research use only, not for in vitro diagnosis or parenterals.
Photo of Wide-Mouth Polycarbonate Erlenmeyer Flask
Suitable for titrations, culture work and other applications where a wide-mouth flask is desirable. Transparent polycarbonate construction. Repeated autoclaving may result in some loss in mechanical strength. Graduated in 25-mL increments. Accepts #8 rubber stopper.
Photo of PTFE Straight-Side Jar
PTFE PFA straight-side jar with PTFE PFA closure. Uniquely suited to handle concentrated acids, highly corrosive liquids, oxidizing agents, solvents and sensitive reagents. For storage of high-purity samples and standards. Ideal for digestion procedures, even where hot acid is used. PFA has excellent chemical resistance and high purity. PFA has a useful temperature range of -270¡C to +250¡C, widest range among fluoropolymers. Jar is autoclavable and performs well in cryogenic applications. Wide mouth gives easy access to contents.
Photo of PolyPaper Pin-Feed Printer Labels
Continuous-feed waterproof PolyPaper labels on heavy-weight backing specifically designed for pin-fed printers. Not intended for use in photocopiers or laser printers. Accommodates standard word processor and database printing. Ideal for use as address labels or identification labels for lab bottles, containers, biological samples, equipment, microscope slides, etc. Special adhesive backing adheres well to plastics, glass and metals. Labels are formatted six across.
Photo of Duplex Laboratory Notebook
Pages are printed on one side only and each page has an identically numbered duplicate page behind it; the book has 50 numbered sets (100 note sheets). Duplicate pages are perforated for easy removal. Carbon paper is not supplied with notebooks. Paper pages with brown polyethylene cover.
Photo of Diuresis Metabolic Cage for Mice
For the collection of by-products from a single mouse. Smaller separating cone and collection funnel minimize evaporation. A stainless steel screen replaces the collection tube for feces separation. Same upper chamber dimensions as Cat. No. N650-0100. Includes feeder assembly, water bottle with cap, and bottle support (not shown in photo.) Each cage includes complete assembly and use instructions, replacements parts list and warranty card. N650-0323 Diuresis Metabolic Cage Adapter Kit for Mice: Converts any standard NALGENE metabolic cage except N650-0315 into a diuresis cage for mice.
Photo of Rodent Cage Adapter Gate
Designed for rats, guinea pigs and hamsters. Includes same fluid collection tubes and rings as the smaller rodent cages and the following componets sized for larger rodents: upper chamber, water bottle and support, feeder assembly and urine collection tube. Each cage includes complete assembly and use instructions, replacement parts list and warranty card. Modify this cage to house smaller rodents by adding adapter gate Cat. No. N650-0358, plus the following components: For mice: Use adapter gate and mouse kit, Cat. No. N650-0300.
Photo of Single-Cage Stand
Stainless steel with nylon supports. Holds one rodent metabolic cage, Cat. No. N650-0100, -0210, -0311, -0322 or -0350. Easy to assemble instructions included.
The red polycarbonate Mouse House* provides an enriched environment that encourages animals to show a wide range of natural behaviors such as jumping, climbing, squeezing through holes and sleeping during daylight hours. Abnormal stereotyped behaviors are reduced. The Mouse House is an easily inspected, closed-environment good for breeding and stock groups of animals. Mice tend to keep the area inside the Mouse House clean. Because mice see red as black, they see the red Mouse House as a secure dark place.
Photo of Drainboard Pipet Washer-Rinser
Low-Density Polyethylene Pipet Washer-Rinser designed for use on sink drainboard. Large siphon tube permits water to be cycled rapidly through pipets. Repeats automatically. Water use may be as low as 1.5 liters per minute. May be connected directly to drainline. When there's a drop in water pressure, water inlet at top eliminates the risk of back-siphoning contaminated water into the water line. Equipped with 1 in. 90¡ elbow for connection to flexible tubing. When used with tubing cut to a length of 6 to 12 in. (152.4 mm to 304.8 mm).

Polysulfone centrifuge tubes are strong and tough like polycarbonate and much more acid- and base-resistant. Can be used up to 50,000xg in refrigerated and non-refrigerated centrifuges must be filled to 80% of the total capacity. With sealing cap closure option. Before autoclaving, just set closure on top of the tube without engaging the threads. All centrifuge ware must be filled to 80% of total capacity for proper performance unless otherwise noted.

ResMer manufacturing technology makes these racks retain there colors and performance in harsh lab invironments. Useful in wide temperature range and good chemical resistance. Each hole has molded-in letters and numbers for easy sample identification. Stackable when empty or full.

Economically priced. Translucent; fluid levels easily seen. Food-Grade materials comply with 21 CFR 177.1520 for food packaging. Nontoxic, odorless and tasteless. Excellent for laboratory and industrial use. Not autoclavable but can be chemically sterilized. Less flexible than NALGENE 180 tubing, but can be bent to facilitate set-ups. Superior chemical resistance.

Photo of NALGENE Repair Kit For PVC Hand-Operated Vacuum Pumps

Maintain and repair the internal parts of your Thermo Scientific™ Nalgene™ Cat. Nos. 6131-series (P9050) and 6132-series (P9060) hand pumps. Thermo Scientific™ Nalgene™ Repairable Hand-Operated Vacuum Pump Repair Kits include everything you need for extended hand pump life.

(Sample Photo Displayed. Individual items may differ from the image shown.)